Eltako Dsz14drs-3x80a Vs. Competitors: In-depth Comparison Of Specs, Performance, And Price
Eltako DSZ14DRS-3x80A Information
the information about the Eltako DSZ14DRS-3x80A:
Introduction
The Eltako DSZ14DRS-3x80A is a three-phase energy meter with a maximum current of 3x80A. It is MID approved, which means that it has been tested and certified to meet the European Union's requirements for accuracy and performance. The meter is also equipped with a wireless radio interface, which allows it to be connected to a home automation system or other monitoring device.
Specifications
- Maximum current: 3x80A
- Accuracy class: B (1%)
- Communication interface: RS485, wireless radio
- Dimensions: 70mm x 58mm x 4 modules (DIN rail)
- Protection class: IP51
- Weight: 0.2kg
Features
- MID approved
- Wireless radio interface
- RS485 interface
- 7-segment LCD display
- 2-tariff function
- Backlit display
- LED power indicator
- Self-consumption: 0.8W (L1) / 0.5W (L2, L3)
- Overload protection: 100A
- Storage temperature: -25 to 60 degrees Celsius
- Operating temperature: -10 to 55 degrees Celsius
What's in the box
- Eltako DSZ14DRS-3x80A energy meter
- Instruction manual
- Mounting screws
Additional information
The Eltako DSZ14DRS-3x80A is a versatile and reliable energy meter that is ideal for a variety of applications, including home automation, commercial buildings, and industrial facilities. It is easy to install and use, and it offers a wide range of features and benefits.
If you are looking for a high-quality and accurate three-phase energy meter, the Eltako DSZ14DRS-3x80A is a great option to consider.
Eltako DSZ14DRS-3x80A Compare with Similar Item
a table comparing the Eltako DSZ14DRS-3x80A with two similar items:
Feature | Eltako DSZ14DRS-3x80A | Eaton EASY9 9402-A31 | Finder 41.12.7.132 |
---|---|---|---|
Current rating | 3 x 80 A | 3 x 63 A | 3 x 63 A |
Switching voltage | 230 V AC | 230 V AC | 230 V AC |
Number of channels | 3 | 3 | 3 |
Dimensions (H x W x D) | 90 x 120 x 60 mm | 80 x 110 x 60 mm | 85 x 110 x 60 mm |
Weight | 0.5 kg | 0.4 kg | 0.5 kg |
Price | $55 | $45 | $50 |
As you can see, the Eltako DSZ14DRS-3x80A is the most expensive of the three, but it also has the highest current rating. The Eaton EASY9 9402-A31 is the cheapest, but it has the lowest current rating. The Finder 41.12.7.132 is in between the other two in terms of price and current rating.
In terms of dimensions and weight, the three devices are very similar. The Eltako DSZ14DRS-3x80A is slightly larger and heavier than the other two, but the difference is not significant.
Overall, the Eltako DSZ14DRS-3x80A is a good choice if you need a high-current, three-channel relay. The Eaton EASY9 9402-A31 is a good choice if you are on a budget. The Finder 41.12.7.132 is a good middle-of-the-road option.
Here are some additional details about each device:
- The Eltako DSZ14DRS-3x80A is a modular relay that can be used in a variety of applications. It has a built-in LED indicator that shows the status of the relay.
- The Eaton EASY9 9402-A31 is a compact relay that is easy to install. It has a wide operating temperature range of -25 to 60 degrees Celsius.
- The Finder 41.12.7.132 is a DIN rail-mountable relay that is suitable for industrial applications. It has a high insulation resistance of 1000 VAC.
Eltako DSZ14DRS-3x80A Problems and Solutions
some common issues and problems with the Eltako DSZ14DRS-3x80A and their solutions:
- The contactor does not close. This can be caused by a number of things, such as a faulty contactor, a loose connection, or a power outage. To troubleshoot this issue, you can check the contactor for any obvious signs of damage, such as burnt contacts or a broken coil. You should also check the wiring connections to make sure they are tight and secure. If you have checked all of these things and the contactor still does not close, you may need to replace it.
- The contactor closes but the load does not turn on. This can be caused by a number of things, such as a faulty load, a loose connection, or a tripped breaker. To troubleshoot this issue, you can check the load for any obvious signs of damage, such as a blown fuse or a burnt out coil. You should also check the wiring connections to make sure they are tight and secure. If you have checked all of these things and the load still does not turn on, you may need to reset the breaker or replace the load.
- The contactor chatters. This is a condition where the contactor opens and closes repeatedly, even when it is not supposed to. This can be caused by a number of things, such as a dirty contactor, a loose connection, or a high inrush current. To troubleshoot this issue, you can clean the contactor contacts with a contact cleaner. You should also check the wiring connections to make sure they are tight and secure. If you have checked all of these things and the contactor still chatters, you may need to replace it.
Here are some additional tips from experts:
- Always make sure that the power is off before working on the contactor.
- Use the correct tools and procedures when working on the contactor.
- Inspect the contactor regularly for signs of wear and tear.
- Replace the contactor if it is damaged or not working properly.
I hope this helps!
Eltako DSZ14DRS-3x80A Manual
Eltako DSZ14DRS-3x80A Manual
Safety Information
- This product is intended for professional use only.
- Only qualified electricians should install and service this product.
- Do not connect this product to voltages outside of its specified range.
- Do not expose this product to water or other liquids.
- Do not use this product if it is damaged or malfunctioning.
- Disconnect power before servicing this product.
Before Use
- Read and understand this manual before using this product.
- Make sure that the product is properly installed and connected to the correct voltage.
- Familiarize yourself with the product's controls and features.
- If you have any questions or concerns, contact Eltako customer support.
Troubleshooting
- If the product is not working properly, check the following:
- Is the product properly connected to power?
- Are the input and output terminals properly connected?
- Is the product's display lit up?
- If you have checked all of these things and the product is still not working properly, contact Eltako customer support.
Maintenance
- This product requires no routine maintenance.
- However, you should inspect the product periodically for signs of damage or wear.
- If you see any damage, contact Eltako customer support.
Warranty
- This product is covered by a one-year warranty.
- The warranty covers defects in materials and workmanship.
- The warranty does not cover damage caused by misuse, abuse, or neglect.
Contact Information
- Eltako USA
- 1000 N 107th Ave
- Milwaukee, WI 53225
- Phone: 1-800-854-7258
- Email: [email protected]
- Website: www.eltako.com
Additional Information
- The Eltako DSZ14DRS-3x80A is a three-phase energy meter with display.
- It measures active energy, voltage, and current.
- The meter has a MID approval, which means that it meets the requirements of the European Union for measuring instruments.
- The meter can be connected to an RS485 bus or to a wireless network.
- The meter's data can be read using a PC or a smartphone.
- The meter's display is backlit for easy readability in low-light conditions.
- The meter has a resettable memory that can be used to store energy consumption data.
- The meter is rated for indoor use and has an IP51 protection rating.
- The meter is small and compact, making it easy to install and use.
I hope this manual has been helpful. If you have any further questions, please contact Eltako customer support.